<?xml version="1.0" encoding="UTF-8" ?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>chrom-L at Yahoo! Groups</title>
    <link>http://tech.groups.yahoo.com/group/chrom-L/</link>
    <description>Chromatography, SPE, LC/MS, HPLC, GC/MS </description>

    <item>
      <title>GCMS noise follow up</title>
      <pubDate>Wed, 10 Sep 2008 14:44:15 GMT</pubDate>
      <dc:creator>nfitzgerald</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2316</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2316</guid>
      <description>Thanks for everyone&#39;s help with my GCMS noise problem.  I thought it might be good to post a follow up.  After replacing the column, injector heater, liner,</description>
    </item>
    <item>
      <title>HPLC of 1,2-dialkylcyclohexanes</title>
      <pubDate>Wed, 27 Aug 2008 12:45:06 GMT</pubDate>
      <dc:creator>Tony Herlt</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2315</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2315</guid>
      <description>27th August 2008 Dear colleagues, We are trying to separate the cis/trans isomers of 1,2-dialkylcyclohexanes by HPLC, the aim ultimately being to obtain up to</description>
    </item>
    <item>
      <title>GCMS noise</title>
      <pubDate>Thu, 24 Jul 2008 18:49:59 GMT</pubDate>
      <dc:creator>nfitzgerald</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2314</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2314</guid>
      <description>Hi, I&#39;m having some noise issues that I&#39;m hoping someone can help me with. I have a HP5890 GC and HP5970 MS.  I recently fixed the injector heater and replaced</description>
    </item>
    <item>
      <title>peroxydation of linoleic acid</title>
      <pubDate>Mon, 31 Mar 2008 14:47:50 GMT</pubDate>
      <dc:creator>noziraf</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2313</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2313</guid>
      <description>Anyone have simple method for preparation of hydroperoxy linoleic acid (13-HPOD and 9-HPOD) and hydroxy linoleic acid (13-HOD and 9-HOD) with linoleic acid ? </description>
    </item>
    <item>
      <title>CrestPak C18 HPLC columns</title>
      <pubDate>Tue, 11 Mar 2008 06:40:28 GMT</pubDate>
      <dc:creator>Tony_Herlt</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2312</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2312</guid>
      <description>11th March 2008 Dear colleagues, Would any of you have information on uS Crestpak C18-S HPLC columns (u represents the Greek letter, mu), specifically,</description>
    </item>
    <item>
      <title>off topic</title>
      <pubDate>Mon, 03 Mar 2008 19:33:26 GMT</pubDate>
      <dc:creator>Guilherme Vannucchi Portari</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2311</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2311</guid>
      <description>Dear Colleagues, Excuse me to use the forum for this help. I&#39;m needing an old article about glutathione dosage. If somebody can send me I will thank a lot. </description>
    </item>
    <item>
      <title>PCB ECD problem</title>
      <pubDate>Mon, 03 Mar 2008 16:36:48 GMT</pubDate>
      <dc:creator>nfitzgerald</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2310</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2310</guid>
      <description>Hi all, I&#39;m hoping someone could help me.  We have started some experiments with PCBs.  We extracted control and PCB spiked sediment samples by soxhlet</description>
    </item>
    <item>
      <title>article request</title>
      <pubDate>Tue, 15 Jan 2008 01:29:35 GMT</pubDate>
      <dc:creator>Guilherme Vannucchi Portari</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2309</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2309</guid>
      <description>Dear colleagues, can somebody send me the article below? Ng HT, Chen CY, Hsieh HM, Leung WY, Ou MC, Tang WL. Amniotic fluid lecithin/sphingomyelin ratio in</description>
    </item>
    <item>
      <title>basic alumina HPLC column</title>
      <pubDate>Mon, 03 Dec 2007 23:45:58 GMT</pubDate>
      <dc:creator>Tony_Herlt</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2308</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2308</guid>
      <description>4th December 2007 Dear colleagues, Would any of you know of a commercial source for an HPLC column packed with basic alumina (pH &gt;= 9), particle size 10 micron</description>
    </item>
    <item>
      <title>Lactic acid analyse</title>
      <pubDate>Mon, 22 Oct 2007 09:37:53 GMT</pubDate>
      <dc:creator>noziraf</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2307</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2307</guid>
      <description>Did someone have experience for quantifying low concentration of lactic acid in rumen juice (10 µg/ml)with HPLC/UV or GC/FID system ? Thanks.</description>
    </item>
    <item>
      <title>Articles</title>
      <pubDate>Thu, 18 Oct 2007 18:06:44 GMT</pubDate>
      <dc:creator>Guilherme Vannucchi Portari</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2306</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2306</guid>
      <description>Dear Colleagues, Can someone send me this article, Lechner M, Rieder J. Mass spectrometric profiling of low-molecular-weight volatile compounds--diagnostic</description>
    </item>
    <item>
      <title>Condionining and ion pair</title>
      <pubDate>Tue, 02 Oct 2007 07:13:23 GMT</pubDate>
      <dc:creator>Khalid ghaffar</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2305</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2305</guid>
      <description>Ion-pairing reagents such as tetra-butyl-ammonium chloride and octanesulfonic acid tend to adsorb to reversed phase stationary phases like C-18, modifying </description>
    </item>
    <item>
      <title>VMA and Ion pairing</title>
      <pubDate>Mon, 01 Oct 2007 17:14:24 GMT</pubDate>
      <dc:creator>Gianfranco Bruno</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2304</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2304</guid>
      <description>Please I need this article or similar: Thank you Gianfranco AU: N. Lammers, J. Zeeman, G. J. De Jong TI: Effect of some parameters on the liquid</description>
    </item>
    <item>
      <title>Condionining and ion pair</title>
      <pubDate>Thu, 20 Sep 2007 16:11:30 GMT</pubDate>
      <dc:creator>Gianfranco Bruno</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2303</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2303</guid>
      <description>Why a C18 Column with a mobile phase with ion pairing conditions on more time than a C18 with a mobile phase without ion pairing? thank you Gianfranco </description>
    </item>
    <item>
      <title>GC/MS autotune questions</title>
      <pubDate>Wed, 18 Jul 2007 20:47:47 GMT</pubDate>
      <dc:creator>creakinator</dc:creator>
      <link>http://tech.groups.yahoo.com/group/chrom-L/message/2302</link>
      <guid isPermaLink="true">http://tech.groups.yahoo.com/group/chrom-L/message/2302</guid>
      <description>Problem:  We are consistently seeing peak(s) around 14-18 amu over 40 abundance in the autotune spectra on an Agilent 5973 MSD connected to an Agilent 6890 GC.</description>
    </item>

  </channel>
</rss>