<?xml version="1.0" encoding="UTF-8" ?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>sweetpea-loco at Yahoo! Groups</title>
    <link>http://finance.groups.yahoo.com/group/sweetpea-loco/</link>
    <description>Sweetpea owners group</description>

    <item>
      <title>superheater</title>
      <pubDate>Mon, 06 Jul 2009 10:36:22 GMT</pubDate>
      <dc:creator>chris hall</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1086</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1086</guid>
      <description>Hi all, I have recently recieved my superheater tubes from Blackgates and have some questions I am hoping you can help with. I am not sure if any of you are</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Mon, 22 Jun 2009 09:12:10 GMT</pubDate>
      <dc:creator>Wilfred L Baker</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1085</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1085</guid>
      <description>Point taken about the pump in the tender Wilf ... From: Kevin Bennett To: sweetpea-loco@yahoogroups.com Sent: Friday, June 19, 2009 11:17 AM Subject:</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Sun, 21 Jun 2009 17:58:14 GMT</pubDate>
      <dc:creator>Brian Sinfield</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1084</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1084</guid>
      <description>Hello Dan; I got your email and I replied to it. However, my computer crashed big time at that time, and I din&#39;t hear back from you, so I am wondering if you</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Sat, 20 Jun 2009 10:35:58 GMT</pubDate>
      <dc:creator>Dan Keen</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1083</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1083</guid>
      <description>Hi Chris, As long as two out of the three systems you have for getting water into the boiler work on the day of the annual steam test you will satisfy the test</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Sat, 20 Jun 2009 05:48:24 GMT</pubDate>
      <dc:creator>Chris Parsons</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1082</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1082</guid>
      <description>Hi all, Thank you all for your interest and responces to the issue of my proposed injector sitting. To repeat the issue, IF I move the the hand pump to the</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Fri, 19 Jun 2009 10:26:21 GMT</pubDate>
      <dc:creator>bill purvis</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1081</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1081</guid>
      <description>... Duncan was referring to the pump output - he has a pump in the tender. Bill -- +---------------------------------------+ ... </description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Fri, 19 Jun 2009 10:17:30 GMT</pubDate>
      <dc:creator>Kevin Bennett</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1080</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1080</guid>
      <description>Hi Wilf, This is a slightly unfortunate use of the phrase &quot;pressurised connections&quot;. If you move the hand pump from the loco to the driving truck/tender the</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Fri, 19 Jun 2009 10:16:26 GMT</pubDate>
      <dc:creator>john_pagett@...</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1079</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1079</guid>
      <description>Wilf, I think he wants the hand pump in the tender, so that feed will be pressurised. Cheers, JohnP</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Fri, 19 Jun 2009 09:25:31 GMT</pubDate>
      <dc:creator>Wilfred L Baker</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1078</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1078</guid>
      <description>Why do you need pressurised connections between tender &amp; loco. It is just a water supply Not pressurised. If some boiler inspectors hear about this they will</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Thu, 18 Jun 2009 08:16:54 GMT</pubDate>
      <dc:creator>Chris Parsons</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1077</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1077</guid>
      <description>Thank you Duncan for you ideas. I will look into the availability of this pipe.  There is a local &#39;shop&#39; that sells all types of pressure fitting for</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Wed, 17 Jun 2009 19:25:03 GMT</pubDate>
      <dc:creator>duncanwebster</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1076</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1076</guid>
      <description>Good stuff for pressurised connections between tender and loco is airline pipe. I used 4mm OD polyurethane, the yellow stuff, it is much more flexible than the</description>
    </item>
    <item>
      <title>Re: water gauge</title>
      <pubDate>Wed, 17 Jun 2009 18:52:00 GMT</pubDate>
      <dc:creator>IAN BARKER</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1075</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1075</guid>
      <description>Thanks for that Wilf i have dug it out tonight funny it in there but not in the book, Ian B ... From: Wilf &lt;wilf.baker@...&gt; Subject: [sweetpea-loco]</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Tue, 16 Jun 2009 13:51:41 GMT</pubDate>
      <dc:creator>Chris Parsons</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1074</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1074</guid>
      <description>Hi to both Nigel and Bill Thank you both for your most interesting and helpful responses to my enquiry I like the idea of removing the handpump and then using</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Tue, 16 Jun 2009 12:30:36 GMT</pubDate>
      <dc:creator>NIGELBALL@...</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1073</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1073</guid>
      <description>Hi All Did mine differently to this, Water from tender to injector on left side where hand pump should be. Hand pump in tender to boiler via additional third</description>
    </item>
    <item>
      <title>Re: Injector</title>
      <pubDate>Tue, 16 Jun 2009 11:57:32 GMT</pubDate>
      <dc:creator>bill purvis</dc:creator>
      <link>http://finance.groups.yahoo.com/group/sweetpea-loco/message/1072</link>
      <guid isPermaLink="true">http://finance.groups.yahoo.com/group/sweetpea-loco/message/1072</guid>
      <description>... I too found the axle pump to be inadequate. It was then bored out and a bigger ram fitted, but still couldn&#39;t keep up. I fitted an injector and that has</description>
    </item>